How Deep Are Utility Lines Buried In Alberta?

The cable is typically buried around 4 feet underground. This depth, however, can vary. Some wires have been discovered at depths of up to 6 feet. Ascertain that the excavation complies with Alberta Occupational Health and Safety Code Part 32. (2009).

In Alberta, how deep is a gas line buried?

DEPTH OF GAS LINE: 24 INCHES UNDER DRIVEWAYS AND PARKING AREAS, 15 INCHES UNDER NON-TRAFFIC AREAS GAS LINE TO BE BURIED FROM RISER TO RISER WITH A CONTINUOUS TRACER WIRE TERMINATING ABOVE FINISHED GRADE. ELECTRICAL CABLE DEPTH: 36 INCHES UNDER DRIVEWAYS AND PARKING AREAS, 24 INCHES UNDER NON-TRAFFIC AREAS ELECTRICAL CABLE DEPTH: 36 INCHES UNDER DRIVEWAYS AND PARKING AREAS

Most utilities are buried at a certain depth.

Furthermore, National Codes specify the depth to which these lines must be buried below ground. Some low-voltage subterranean lines may be as shallow as 18 inches, whereas the majority of higher-voltage circuits will be at least 24 inches deep.

In Calgary, how deep are utility lines?

A shallow utility provider is described as one that installs underground infrastructure in the road right-of-way at depths ranging from 0.9 m to 2.0 m.

How far can you go before you have to contact Alberta?

This figure comes from the Common Ground Alliance (CGA), and if it sounds disturbingly high to you, it’s because many people are unaware that they must call 811 before digging.

While the ground may not have thawed where you are, April is National Safe Digging Month, and it’s a good reminder to know what you need to do before breaking ground on this year’s projects.

According to data collated by CGA from various industry associations, there are more than 100 billion feet of subsurface utilities in the United States, so you can’t assume your customer’s property is free of them.

There is no limit to how deep a person can go before calling 811. CGA advises that any time you put a shovel in the ground, whether it’s to plant little shrubs or build a fence, you should contact because many utilities are buried just a few inches below the surface.

Even if an area has been designated previously, erosion and root system growth might change the depth or location of buried wires, so call each time you start a job.

Calling 811 is also not an optional chore, as every state has a different statute that requires people to contact before digging. While the amount of time you have to call 811 before digging differs by state, you can find your state’s standards here.

It is a frequent misperception that dialing 811 costs money; nevertheless, dialing 811 is completely free. Utility companies cover the cost to protect you, your staff, and your customers. When you don’t call, hit a utility line, and are held liable for the damage, the true expenses effect your business.

Some utility companies charge not just for the expense of dispatching a staff to repair or replace the damaged property, but also for the loss of service caused by the outage.

In recent years, some states have enacted penalties and fines to aid in the enforcement of the law. Mississippi passed a law in 2016 requiring first-time offenders to complete a compliance training course.

Second-time offenders within a five-year period must complete a training course or face a fine of up to $500 per offense. Malicious activities with the aim to destroy subsurface lines result in a training course and fines of up to $5,000 per event for third-time crimes in a five-year period.

Here’s how the 811 system works and what to expect:

  • Two to three days before digging, call 811 or submit an online request to your local one-call center.
  • The affected utility companies will be notified by the one-call center. Wait two to three days for the utility operators to react to your request (this varies by state). For each request, an average of seven to eight operators are notified.
  • Verify that all of the operators who are affected have responded to your request. The process for confirmation varies by state.
  • Dig around the designated locations with care. The majority of state rules prevent machines from being used within 18 to 24 inches of a utility that has been marked. Hand dig or use vacuum excavation if you need to dig closer.

Keep in mind that depending on the state, the locate ticket is only good for a set amount of time, and if you want to continue, you’ll need to call 811 for a re-mark.

Stop working immediately if one of your employees accidentally hits a pipeline. The processes that follow differ depending on the type of utility line hit.

When dealing with natural gas, propane, or petroleum lines, leave the area and contact 911 as well as the facility operator. Don’t do anything that could start a blaze, and make sure everyone is aware of the situation. Keep the public out by cordoning off the area. Stay away from the gas and do not attempt to repair the pipe on your own.

Warning everyone in the area, including emergency responders, that the ground and objects near the point of contact may be energized in the case of electrical wires.

If you have a radio or phone, call the electricity utility operator or the fire department. Otherwise, stay on the excavator and ask someone to call for utility and emergency help.

Those near the excavator or point of contact should keep both feet together and remain still. They must not come into contact with the excavator or the material. Only leave the excavator and the surrounding area after an official from the electric utility has declared it safe. If a fire, explosion, or other hazard requires quick evacuation, jump (not step) from the apparatus and land with both feet. Make sure you’re at least 25 to 30 feet away. Take no ordinary walking steps.

Notify the facility owner of any damaged communications cables, and do not study or stare at broken, severed, or disconnected fibers. Keep a safe distance away and block the area to keep others out.

Contact the pipeline operator after examining the situation and ensuring that nothing appears to be harmed. Minor nicks or dents can lead to major issues in the future.

If a homeowner has consulted you but intends to do it themselves, remind them that calling 811 isn’t just for professionals; anyone planning to dig must dial this number.

What is the minimum depth at which natural gas pipes must be buried?

(1)All pipe, tubing, fittings, and other piping components between the tank and the first shutoff valve must be designed with a factor of safety of at least 8 based on the minimum specified tensile strength at room temperature for the full range of pressures, temperatures, and loadings to which they may be subjected.

All other pipe, tubing, fittings, and other pipeline components must be adequate for the full range of pressures, temperatures, and loads to which they may be exposed, with a factor of safety of at least four.

For plumbing systems with a working pressure more than 100 psi, underground piping must never be less than Schedule 80.

Any material utilized, including gaskets and packing, must be compatible with natural gas and the conditions in which it is used.

(2)All piping and tubing must be run as close to the source as possible, with suitable allowances for expansion, contraction, jarring, vibration, and settling.

Exterior pipe must be well supported and protected against mechanical damage, whether buried or put aboveground.

Unless otherwise protected, underground plumbing must be buried at least 18 inches below the ground’s surface.

All underground piping must be coated to prevent corrosion in accordance with Section 533(b) or an equivalent standard.

For piping below ground, zinc coatings (galvanizing) are not considered enough protection.

(3)All welded piping must be manufactured and tested in conformity with the ANSI Code for Pressure Piping, Petroleum Refinery Piping, B31.3, 1966 Edition or a similar code.

(4)All valves must be capable of withstanding the whole range of pressure and temperature that they may be exposed to.

The service ratings must be stamped or otherwise permanently marked on the valve body by the manufacturer.

Strainers, snubbers, and expansion joints, among other piping components, must be permanently marked by the manufacturer to show the service ratings.

All materials, such as valve seats, packing, gaskets, and diaphragms, must be resistant to natural gas action in the circumstances they are exposed to.

(5)It is forbidden to use the following:

(A)Valves, cocks, fittings, and other piping components made of cast iron or semisteel that do not comply with ASTM Specifications A-536-67, Grade 60-40-18; A-395-68; A-47-68, Grade 35018; and A-445-66 unless they have pressure-temperature ratings of at least 1 1/2 times the design service conditions.

Valves made of cast iron or semisteel that do not meet the three ASTM criteria specified above should not be utilized as primary stop valves.

(C)Valves with a design that allows the valve stem to be removed without disassembling the valve body or removing the entire valve bonnet.

(D)Plastic pipe, tubing, hose, and fittings, unless the Division has given written approval.

(E)Valves having valve stem packing glands that cannot be repacked under pressure unless they are separated from the vessel by another stop valve of an appropriate kind.

Service valves are exempt from this rule.

(F)Aluminum tubing for outside applications, as well as threaded aluminum connections and adapters that must be attached or removed as part of the filling or transferring operation for those connections and adapters with unique threads suitable for this service.

Compressed Natural Gas (CNG) is a type of natural gas that has been compressed.

Hose shall not be utilized in place of manifolds, pipelines, or tubing between dispensing tanks and cylinders and the loading and/or unloading hose connections, except that a segment of metallic hose not exceeding 24 inches in length may be used in each pipeline to offer flexibility where needed.

Each section must be fitted in such a way that it is shielded from mechanical harm and is easily visible for inspection.

Each section must include the manufacturer’s identification.

(1)On liquid lines between the tank and the first shutdown valve, flanged or threaded joints that have not been seal welded are forbidden.

(3)Except as provided in 536(c), piping with a diameter of 2 inches or less may be threaded, welded, or flanged (1).

(5)The plugs must be solid or bull plugs made of at least Schedule 80 seamless pipe.

(6)Threaded pipe and tubing with compression type couplings may be utilized for service temperatures of minus 20 degrees Fahrenheit or above, except as prohibited in 536(c) (2).

(7)Pipe supports for piping with a service temperature below minus 20 degrees Fahrenheit must be built to prevent support steel embrittlement by minimizing heat transfer.

(8)In low-temperature usage, bellows type expansion joints must have exterior insulation to prevent ice from accumulating on the bellows.

1.Amendment to subsections a)(1) and a)(5)(F) filed 3-29-74; effective the thirty-first day after that (Register 74, No. 13).

Is there a minimum cable depth for electricity?

Underground electricity wires are normally hidden in ducts between 0.45m and 1m below ground level, or may be covered with a layer of tiles, boards, or colored plastic tape about 150mm above ground level.

What happens if I dig and come upon a water line?

Calling 811 before you dig is the most important step you can take to avoid an accident. When homeowners and contractors dial 811, a team of experts connects them with a team of experts who notify the proper utility providers of the requester’s purpose to dig. A team of professional locators is then dispatched to the excavation site to use color-coded paint and flags to indicate the locations of subsurface utilities.

Fast Fact: An underground utility line is broken every 6 minutes because someone decided to dig before dialing 811.

Even a single line struck when digging can result in significant injury, fines, hefty repair expenses, and power interruptions. So, even if you’re only excavating a few inches underground, we strongly advise you to have your utilities marked so you don’t accidentally hit one. Calling 811 before you start your project, whether you’re hiring a professional or doing it yourself, is smart digging!

What is the depth of the gas lines in Edmonton?

Driveways and parking areas are 24 inches deep, whereas non-traffic zones are 15 inches deep. A constant compression wire will be used to burn the gas line from Riser to Riser.